中国科学院数学与系统科学研究院期刊网

Figure/Table detail

A Secure Cryptographic System Based on SSVEP Brain-Computer Interface Technology
Xu XIAO, Feiyang ZHANG, Wenhan YIN, Dezhi ZHENG
Journal of Systems Science and Information, 2024, 12(3): 423-432.   DOI: 10.21078/JSSI-2023-0113

Target Stimulation target frequency Phase difference Test times Correct times Accuracy
Subject # 1 Subject # 2 Subject # 1 Subject # 2
Key 1 10.3 Hz 0 12 12 12 100% 100%
Key 2 10.8 Hz 0 12 12 12 100% 100%
Key 3 11.3 Hz 0 12 12 10 100% 83.33%
Key 4 11.8 Hz 0 12 11 12 91.70% 100%
Key 5 12.3 Hz 0 12 12 12 100% 100%
Key 6 12.8 Hz 0 12 11 12 91.70% 100%
Key 7 13.3 Hz 0 12 12 12 100% 100%
Key 8 13.8 Hz 0 12 12 12 100% 100%
Key 9 14.3 Hz 0 12 11 12 91.70% 100%
Key 0 14.8 Hz 0 12 12 12 100% 100%
Delete key 15.3 Hz 0 12 12 11 100% 91.7%
Confirm key 15.8 Hz 0 12 11 12 91.70% 100%
Average accuracy 97.2% 97.9%
Table 1 Accuracy of the SSVEP-BCI secure system
Other figure/table from this article